DEPTH/LEVEL:
DRUCK SUBMERSIBLE
PRESSURE LEVEL SENSORS
Model |
Pressure
Type |
Output |
Accuracy
(%F.S.) |
Certifications |
Comments |
PDCR 35/D |
Guage |
10 mV/V |
±0.1% FS |
CE |
0.39” Diameter, Titanium Body
Water Applications |
PDCR 1230 |
Gauge
Absolute |
10 mV/V |
±0.25% FS |
CE, FM, CSA ,“IS” |
0.69” Diameter, Titanium Body
Water Applications |
PDCR 1830 |
Gauge
Absolute |
10 mV/V |
±0.1% FS (Std)
±0.06% FS (Opt) |
CE, FM, CSA, ATEX, ”IS” |
0.69” Diameter, Titanium Body
Water Applications |
PDCR 1840 |
Gauge
Absolute |
10 mV/V |
±0.1% FS |
CE, ATEX, “IS” |
0.69” Diameter, Titanium Body
Water Applications
Hytrel 6108 Cable (hydrocarbon resistant). |
PDCR 1280 |
Gauge
Absolute |
10 mV/V |
±0.25% FS |
CE, FM, CSA, ”IS” |
0.69” Diameter Titanium,
Tefzel Cable
Corrosive Liquids |
PDCR 1880 |
Gauge
Absolute |
10 mV/V |
±0.1% FS |
CE, FM, CSA, ”IS” |
0.69” Diameter, Titanium,
Tefzel Cable
Corrosive Liquids |
PDCR 1730 |
Gauge
Absolute |
10 mV/V |
±0.25% FS |
CE |
0.69” Diameter, Stainless Steel,
Water Applications |
PDCR 1740 |
Gauge
Absolute |
10 mV/V |
±0.25% FS |
CE |
0.69” Diameter, Stainless Steel,
Water Applications,
Hytrel 6108 Cable (hydrocarbon resistant). |
|
Model |
Pressure
Type |
Output |
Accuracy
(%F.S.) |
Certifications |
Comments |
PTX 1230 |
Gauge
Absolute |
4-20 mA |
±0.25% FS |
CE, FM, CSA, “IS” |
0.69” Diameter, Titanium,
Water Applications |
PTX 1830 |
Gauge
Absolute |
4-20 mA |
±0.1% FS (Standard)
±0.06% FS (Optional) |
CE, FM, CSA, ATEX, ”IS” |
0.69” Diameter, Titanium,
Water Applications |
PTX 1840 |
Gauge
Absolute |
4-20 mA |
±0.1% FS |
CE, ATEX, “IS” |
0.69” Diameter, Titanium,
Water Applications,
Hytrel 6108 Cable (hydrocarbon resistant) |
PTX 1835
PTX 1235 |
Gauge
Absolute |
4-20 mA |
±0.1% FS (PTX 1835)
±0.25% FS (PTX 1235) |
Consult Factory |
0.69” Diameter, Titanium,
Water Applications,
Lightening Protection |
PTX 1280 |
Gauge
Absolute |
4-20 mA |
±0.25% FS |
CE, FM, CSA ”IS” |
0.69” Diameter, Titanium,
Tefzel Cable,
Corrosive Liquids |
PTX 1880 |
Gauge
Absolute |
4-20 mA |
±0.1% FS |
CE, FM, CSA ”IS” |
0.69” Diameter, Titanium,
Tefzel Cable,
Corrosive Liquids |
PTX 1885
PTX 1285 |
Gauge
Absolute |
4-20 mA |
±0.1% FS (PTX 1885)
±0.25% FS (PTX 1285) |
Consult Factory |
0.69” Diameter, Titanium,
Tefzel Cable,
Corrosive Liquids,
Lightening Protection |
PMP 1290 |
Gauge
Absolute |
0-5 Vdc |
±0.25% FS |
CE, UL, cUL, “IS” |
1” Diameter, Titanium,
Waste Water Applications |
PTX 1290 |
Gauge
Absolute |
4-20 mA |
±0.25% FS |
CE, UL, cUL, “IS” |
1” Diameter, Titanium,
Waste Water Applications |
PTX 1730 |
Gauge
Absolute |
4-20 mA |
±0.25% FS |
CE |
0.69” Diameter, Stainless Steel,
Fixed Ranges
Water Applications |
PTX 1740 |
Gauge
Absolute |
4-20 mA |
±0.25% FS |
CE |
0.69” Diameter, Stainless Steel,
Fixed Ranges,
Water Applications,
Hytrel 6108 Cable, (hydrocarbon resistant) |
RTX 1930 |
Gauge
Absolute |
4-20 mA |
±0.1% FS (Standard)
±0.06% FS (Optional) |
None |
1” Diameter, Stainless Steel,
Rangeable 4:1
Water Applications |
|